# | Img | Title | Type | Language | View |
1. |
|
Aube Technologies Electric Heater TH146 N DE ManualTH146-N-DE
Installation Guide
Non-programmable Heat Pump Controller
AC144-03 Outdoor Temperature Sensor TH146 User Console CT280-HP-2H1C Control Module
1. Introduction 1.1
Applications
The TH146-N-DE electronic controller can be used to control a heat pump system. The following devices can be connected to the controller: heat pump auxiliary heating (furnace) air recirculation fan humidifier dual-register meter (dual energy) remote control device (for the unoccupied mode)
2. In... Brands:Aube |
User Manual |
ENGLISH |
[View] |
2. |
|
Aube Technologies Fan RT850 ManualRT850
Installation Instructions
Electric Heating Solid-State Relay
n
Application
1.
p
Typical Wiring Diagrams
3.
The RT850 Solid State Relay is designed to control a line-voltage resistive load from a 24 VAC control signal or from signal sources of 4 to 32 VDC. It can be used with fast-commuting thermostat (e.g. cycles of 15 seconds). The RT850 is compatible with both mechanical and 2-wire or 3-wire electronic thermostats (with or without batteries).
I
WARNING: In the ... Brands:Aube |
User Manual |
ENGLISH |
[View] |
3. |
|
Aube Technologies Heat Pump RC845 ManualRC845 - Installation Instructions
Heat Pump Add-On Fossil Fuel Relay
RC845
Application
The RC845 is designed to control either a gas, oil furnace burner or an electric furnace as well as the fan when adding a heat pump on an existing heating system. The RC845 includes a low voltage dry contact output to activate the auxiliary heating system, and a line voltage contact output to control the fan operation. When installed with an Aube heat pump thermostat (TH144HP), the installer can configur... Brands:Aube |
User Manual |
ENGLISH |
[View] |
4. |
|
Aube Technologies Heat Pump TH146 P DE ManualTH146-P-DE
Installation Guide
Programmable Heat Pump Controller
-
TH146-P User Console
CT280-HP-2H1C Control Module
AC144-03 Outdoor Temperature Sensor
1. Introduction 1.1
Applications
The TH146-P-DE programmable controller can be used to control a heat pump system. The following devices can be connected to the controller: heat pump auxiliary heating (furnace) air recirculation fan humidifier dual-register meter (dual energy) remote control device (for the unoccupied mode)... Brands:Aube |
User Manual |
ENGLISH |
[View] |
5. |
|
Aube Technologies Plumbing Product TI034 3W ManualTI034-3W
Installation and User Guide
Programmable Wall Switch
n
Applications
1.
The TI034-3W switch can be used in a single-pole or 3-way installation with the following types of lighting:
Incandescent Halogen Low-voltage halogen with transformer Fluorescent
p
n o p
Power-on
Reset Control (4) On/Off selector
3.
Pry the switch door open from the bottom using a small screwdriver. Ensure the ON/OFF selector is set to ON.
The TI034-3W switch cannot be used wit... Brands:Aube |
User Manual |
ENGLISH |
[View] |
6. |
|
Aube Technologies Plumbing Product TI035 ManualTI035
Installation and User Guide
Programmable Wall Switch
n
Applications
Maximum load 2400 W (20 A @ 120 V) Examples incandescent lights halogen lights block heater fluorescent lights compact fluorescent lights (CFL) sodium lamps electronic ballasts pool filter pumps fans
1.
The TI035 programmable wall switch has been designed to control lightings and motors: Load type Resistive load
Manual Mode The programmable switch operates as a regular switch. Briefly pr... Brands:Aube |
User Manual |
ENGLISH |
[View] |
7. |
|
Aube Technologies Plumbing Product TI052A 3W ManualEXISTING 3-WAY INSTALLATION
To replace a 3-way switch with this wall switch, use the following diagram :
PROGRAMMABLE WALL SWITCH MODEL TI052A-3W / 3-WAY
FOR ALL LIGHTING
THE MAXIMUM LOAD MUST NOT EXCEED 500W/230V
THE TI052A-3W WALL SWITCH CAN OPERATE ON :
ballast equipped installations such as : fluorescent lamps, sodium lamps, etc. incandescent and halogen lighting contactor equipped installations, ceiling fan, block heater, etc.
The " common " wire identified on the removal 3... Brands:Aube |
User Manual |
ENGLISH |
[View] |
8. |
|
Aube Technologies Switch T1034 3W ManualTI034-3W
Installation and User Guide
Programmable Wall Switch
n
Applications
1.
The TI034-3W switch can be used in a single-pole or 3-way installation with the following types of lighting:
Incandescent Halogen Low-voltage halogen with transformer Fluorescent
p
n o p
Power-on
Reset Control (4) On/Off selector
3.
Pry the switch door open from the bottom using a small screwdriver. Ensure the ON/OFF selector is set to ON.
The TI034-3W switch cannot be used wit... Brands:Aube |
User Manual |
ENGLISH |
[View] |
9. |
|
Aube Technologies Switch T1073 ManualTI073
User guide
7-day Solar Programmable Wall Switch
n o
n o p q
Applications
Halogen Low-voltage halogen with transformer Fluorescent
1.
p q
Quick Start-up
Set the time and date before using the switch for the first time.
3.
The TI073 programmable wall switch can be used in a single-switch or 3-way installation with the following types of lighting: Incandescent
The TI073 switch cannot be used with a load of less than 40 W or more than 500 W.
The TI073 wi... Brands:Aube |
User Manual |
ENGLISH |
[View] |
10. |
|
Aube Technologies Switch TI073 3W ManualSwitches
TI073-3W
Do-it-yourself installation and both the flexibility of 7-day programming and the convenience of automatic sunset / sunrise activation
MODEL & RATINGS
For Lights
TI073-3W
500 W max./ 40 W min.
120 V, 60 Hz
4 A (R)
SPECIFICATIONS
FEATURES
PROGRAMMING 7-day programming, up to 42 events Solar timetable can be used simultaneously with daily programs *
Sleek design mounts flush with wallplate
Works with incandescent, halogen and fluorescent light... Brands:Aube |
User Manual |
ENGLISH |
[View] |
|
11. |
|
Aube Technologies Switch TI073 ManualTI073
User guide
7-day Solar Programmable Wall Switch
n o
n o p q
Applications
Halogen Low-voltage halogen with transformer Fluorescent
1.
p q
Quick Start-up
Set the time and date before using the switch for the first time.
3.
The TI073 programmable wall switch can be used in a single-switch or 3-way installation with the following types of lighting: Incandescent
The TI073 switch cannot be used with a load of less than 40 W or more than 500 W.
The TI073 wi... Brands:Aube |
User Manual |
ENGLISH |
[View] |
12. |
|
Aube Technologies Switch Tlo Manual50-1163
... Brands:Aube |
User Manual |
ENGLISH |
[View] |
13. |
|
Aube Technologies Telephone CT240 ManualCT240 Telephone Controller
I n s tall ati on I n s tru c ti on s an d U ser M an u al
1 . Introduction
The CT240 telephone controller is designed to remotely control your home's thermostat. It is possible to command a temperature decrease (Unoccupied) during a prolonged absence or a temperature increase (Comfort) before you return home. Depending on your thermostat's operating characteristics, it either connects to the Aube output (for most Aube models) or to the auxiliary output. When the ... Brands:Aube |
User Manual |
ENGLISH |
[View] |
14. |
|
AUBE TECHNOLOGIES TH104PLUS Manual TH104PLUS
User Guide
Programmable Thermostat
... Brands:AUBE |
User Manual |
ENGLISH |
[View] |
15. |
|
Aube Technologies Thermometer TE501 ManualTE501
User's Guide Digital thermometer
_ _ ___!_______ 1. Description The TE501 digital thermometer displays indoor and outdoor temperatures simultaneously. The thermometer's memory holds minimum and maximum temperature readings, which can be displayed on screen. 2. Installation 2.1 Battery Open the battery compartment (found on the back) by pulling down on the tab at the top of the battery cover. Insert the AAA battery (included). 2.2 Thermometer 2.1 Use the bracket on the back of the thermom... Brands:Aube |
User Manual |
ENGLISH |
[View] |
16. |
|
Aube Technologies Thermostat 50 1133 Manual50-1133
... Brands:Aube |
User Manual |
ENGLISH |
[View] |
17. |
|
Aube Technologies Thermostat AC146 410 ManualAC146-410
Temperature Sensor / Sonde de temprature / Sonda de temperatura
Introduction
The AC146-410 sensor is designed to be used with Aube thermostats and controllers to measure the temperature inside an air duct or air chamber. It can be also used in various other applications.
Installation
Use twisted pair cable for the sensor connection. The maximum allowable distance between the sensor and Aube's controller is 50 feet (15 m). The sensor must be installed so the reading hole i... Brands:Aube |
User Manual |
ENGLISH |
[View] |
18. |
|
Aube Technologies Thermostat CT230 120GA ManualMASTER THERMOSTATS TH113-A/F/AF (12VDC) TH114-A/F/AF (12VDC) TH115-A/F/AF (12VDC) TH116-A/F/AF (12VDC)
Installation Instructions
SLAVE UNITS CT230-120GA CT230-120GB CT230-240GA CT230-240GB
1. Introduction
This master and slave unit system is specially designed for large floor heating applications exceeding 15 A. The master thermostat controls a single or multiple floor heating zones driven by slave units. The master thermostat can control up to 10 slave units. Each slave unit drives it... Brands:Aube |
User Manual |
ENGLISH |
[View] |
19. |
|
Aube Technologies Thermostat CT230 120GB ManualMASTER THERMOSTATS TH113-A/F/AF (12VDC) TH114-A/F/AF (12VDC) TH115-A/F/AF (12VDC) TH116-A/F/AF (12VDC)
Installation Instructions
SLAVE UNITS CT230-120GA CT230-120GB CT230-240GA CT230-240GB
1. Introduction
This master and slave unit system is specially designed for large floor heating applications exceeding 15 A. The master thermostat controls a single or multiple floor heating zones driven by slave units. The master thermostat can control up to 10 slave units. Each slave unit drives it... Brands:Aube |
User Manual |
ENGLISH |
[View] |
20. |
|
Aube Technologies Thermostat CT230 240GA ManualMASTER THERMOSTATS TH113-A/F/AF (12VDC) TH114-A/F/AF (12VDC) TH115-A/F/AF (12VDC) TH116-A/F/AF (12VDC)
Installation Instructions
SLAVE UNITS CT230-120GA CT230-120GB CT230-240GA CT230-240GB
1. Introduction
This master and slave unit system is specially designed for large floor heating applications exceeding 15 A. The master thermostat controls a single or multiple floor heating zones driven by slave units. The master thermostat can control up to 10 slave units. Each slave unit drives it... Brands:Aube |
User Manual |
ENGLISH |
[View] |
21. |
|
Aube Technologies Thermostat CT230 240GB ManualMASTER THERMOSTATS TH113-A/F/AF (12VDC) TH114-A/F/AF (12VDC) TH115-A/F/AF (12VDC) TH116-A/F/AF (12VDC)
Installation Instructions
SLAVE UNITS CT230-120GA CT230-120GB CT230-240GA CT230-240GB
1. Introduction
This master and slave unit system is specially designed for large floor heating applications exceeding 15 A. The master thermostat controls a single or multiple floor heating zones driven by slave units. The master thermostat can control up to 10 slave units. Each slave unit drives it... Brands:Aube |
User Manual |
ENGLISH |
[View] |
|
22. |
|
Aube Technologies Thermostat programmable thermostat ManualTH110-DP-P
Owner's Guide
Programmable Thermostat
Description
1.
This programmable thermostat can be connected to an electric heating system such as an electric baseboard, a radiant ceiling, a floor heating system, an electric convector, etc. It is not compatible with a central heating system.
#
Configuration
3.
The configuration switches are on the back of the thermostat. Default (factory) settings are inside the gray cells. Configurations Not used Early Start a Time... Brands:Aube |
User Manual |
ENGLISH |
[View] |
23. |
|
Aube Technologies Thermostat RC840T ManualRC840T
Installation Guide
On/Off Switching Electric Heating Relay with Built-in 24 V Transformer
n
Application
1.
p q
The RC840T Electric Heating Relay is designed to control a line voltage resistive load from a low voltage thermostat. The RC840T relay has a built-in 24 V transformer and is compatible with 3-wire (R,C,W) thermostats as well as 2-wire mechanical and batteryoperated thermostats. The RC840T operates silently and can be installed in bedrooms, living rooms, or any ot... Brands:Aube |
User Manual |
ENGLISH |
[View] |
24. |
|
Aube Technologies Thermostat TA7210 ManualSystem Installation Guide
EConnectTM Wireless Thermostat Kit TA7210 With Equipment Interface Module
Installation guide for: Wireless equipment interface module EConnectTM wireless thermostat Wireless remote control Wireless outdoor air sensor
IMPORTANT INSTRUCTIONS
ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation. Must be installed by a certified electrician. Read these instructions carefully. Failure to follow these i... Brands:Aube |
User Manual |
ENGLISH |
[View] |
|
25. |
|
Aube Technologies Thermostat TH101A Manual3) Connecting wires and mounting thermostat
Connect the rear thermostat wires to the power supply and to the electric heater wires using solderless connectors for copper wires. See schematic
MODEL TH101A
INSTALLATION
This thermostat has been designed to operate with any installation which has a resistive load (not exceeding 4000W / 240Vac or 2000W / 120Vac) such as electric baseboards, radiant ceilings and floors, electric convectors, etc. IT IS NOT COMPATIBLE WITH A LOW VOLTAGE CONTROLLER... Brands:Aube |
User Manual |
ENGLISH |
[View] |